Katharina:
Reducing the titanium X-rays --> PE covering
Trying to investigate which glue to use
Working with Silicon drift detector, obtained a resolution of 100-200 eV
How to deal with the Lithium target
Al-laminate pouch
Michael:
Calibration:
Peak assignment finalized
~4.4 MeV from excited state of C12 --> populated by Am-Be source!
Fitting pulses:
Used average pulse of Neutrons/Photons in a small energy window.
Extract parameters to fix them for overflow determination
Not very promising for now, looks worse somehow --> Michael will follow up on this
Stella:
Curium analysis:
Waiting for Natalia's input
3d-2p showed no change with inclusion of magnetic dipole, which is impossible
Frederik:
Talking to PSI ICT for the new backup system
Working on getting the DAQ live
Thomas:
Invited to speak about muX at a conference