Andreas:
Detector array: Frame prepared. MIXE will use their drift chamber, so downstream detectors still need to be placed in
Autofilling: New system, filling on each arm --> Goes quite slow, we need to have a look at that
Michael:
Recalibrating after gain drift correction:
- Gaussian fits from -1 sigma --> ~20 eV residual remaining around 700 keV (potassium 2p-1s)
- Hypermet+gaussian+step --> Similar values --> Energy calibration seems quite well under control
Remark from Frederik: We should be careful with INL errors (local non-continuous behavior in the ADC)
We should change the dynamic range for running potassium
Trapezoid filter optimization:
- Saving 50k clock ticks to tune detectors offline --> Threshold high to avoid collecting data on Compton
- Fit exponential tail of waveforms (~1000 events) --> Fit in narrow range provides slight difference with full range (use narrow range!)
- Trapezoid is flat within less than 1 adc channel
- Next up: optimize gap and peaking time --> Michael will follow up on this
Analyzer updates: (see elog entries for details)
- Bug fixes
- Tree writer can now also save raw germanium events (mainly intended for trapezoid optimization)
- Addition of exact extrapolation method for ELET
- For any specific requests ask Frederik or Michael
Frederik:
Request Andreas: Update midas for beamtime? Set point interface in midas?
Request Michael: Analysis during beamtime, rerunning the analyzer to do gaindrift correction
VME + DAQ PC are currently out (some tests will be done with the clover at PSI): When the wall goes up, Cesar wants to do some tests for Quartet
Stella:
Filling with new system takes long. ~45 mins for one previously filled detector yesterday --> Looking for a solution, Stella will follow up on this
Publication on 2022 data:
General idea: Focus on different targets and their capture rate; do not put too much focus on target making and it's issues
Stella will check once more on the intensities with the cascade code