Speaker
Marc Persoz
(Universität Bern)
Description
Neutron grating interferometers can be employed as powerful tools to perform high-precision measurements of deflection angles and scattering. A novel concept of a symmetric Talbot-Lau interferometer using absorption gratings is under development at the University of Bern. The ultimate goal of this project will be a sensitive measurement of the neutron electric charge. Currently, a proof-of-principle apparatus is being investigated at the cold neutron beamline BOA at the Paul Scherrer Institute. On the proposed poster, a description of the experiment, first experimental results concerning the setup, and the achievable sensitivities will be presented.
Primary author
Marc Persoz
(Universität Bern)